型號/MODEL
|
JH-0.3
|
|
描述/Description
|
制氫量≤1Nm³/h, 具有高壓力低露點 ,提供氫燃料電池所需的高品質氫氣。
Hydrogen production capacity ≤1Nm³/h, with high pressure and low dew point, to provide high-quality hydrogen required for hydrogen fuel cells.
|
制氫能力/HYDROGEN PRODUCTION
|
標況速率/
Ntional Production Rate
|
0.3Nm3/h
0.6Kg/24h
|
|
電解槽額定功率/ Rated Power of Electrolyzer
|
1.3kW
|
|
能耗/
Energy Consumption
KWh/Nm3@1.5A/cm2
|
4.6 kWh/Nm3
51 kWh/kg
|
輸氫壓力/Delivery Pressure-Nominal
|
3MPa
|
純度/Purity
|
>99.995%
H2O < 10ppm,O2 < 2ppm, N2 < 2ppm
|
露點/Dew Point
|
< -40℃
|
調節(jié)范圍/Turndown Range
|
0% ~120%
|
電氣規(guī)格/ELECTRICAL SPECIFICATIONS
|
電力需求/Electrical Requirements
|
單相交流210V~240V,50Hz
210 to 240VAC,single phase,50Hz
|
***小需求功率/Minimum Power Required
|
1.5 kVA
|
|
供水要求/WATER REQUIREMENTS
|
***大耗水量/Consumption Rate at Maximum Production
|
0.3L/hr
|
|
水質要求/Water Quality
|
> 1MΩ·cm(<1μS/cm)
|
水溫/Temperature
|
5 ~ 50℃
|
水壓/Pressure
|
0.5~2 barg
|
冷熱要求/HEAT LOAD AND COOLANT REQUIREMENTS
|
冷卻/Coolant
|
風冷/Air-cooled
|
連接接口/INTERFACE CONNECTIONS
|
產氫接口/
H2 Product Port
|
DN6
|
氫/水排水接口/
H2/ H2O Vent Port
|
DN6
|
氧氣排氣口/
O2 Vent Port
|
DN10
|
進水接口/DI Water Port
|
DN10
|
排水接口/Drain Port
|
DN10
|
電氣接口/Electrical
|
三孔插頭/Three-Prong Plug(Less than 2.5kW)
單相斷路器/ Single-phase circuit breaker (More than 2.5kW)
|
通訊接口/ Communication Interface
|
RS485串口
|
控制系統(tǒng)/CONTROL SYSTEMS
|
控制/Control
|
PLC
|
工作模式/ Work Pattern
|
1.網電供應運行/ Grid power supply operation
2.可再生能源供應運行/ Renewable energy supply runs
|
標準特性/Standard Features
|
一鍵啟停、超壓報警 、缺水報警 、水滿報警、超溫報警 、氫氣泄漏報警 、水質檢測報警
One-button start and stop, overpressure alarm, water shortage alarm, water full alarm, overtemperature alarm, hydrogen leakage alarm, water quality detection alar
|
物理特性/PHYSICAL CHARACTERISTICS
|
尺寸/Dimensions
L*W*H
|
600*330*530
|
800*430*630
|
|
重量/Weight
|
45kg
|
65kg
|
|
IP 評級/IP Rating
|
IP22
|
運行環(huán)境建議/ENVIRONMENTAL CONSIDERATIONS
|
標準位置/Standard Siting Location
|
室內、水平擺放±10、濕度≤90%無冷凝
Indoor,level±10,0 to 90%RH non-condensing
|
工作環(huán)境溫度/Ambient Temperature Range
|
1 ~ 60℃
|
工作海拔/Altitude Range – Sea Level
|
≤2000m
|
房間通風/Room Ventition
|
需要從安全風源位置提供適當通風
Proper ventilation from a safe air source location is required
|
其他
|
噪音 (一米距離)
Noise(1meter)
|
<55 dB(A)
|
附帶功能/ Incidence Function
|
氮氣吹掃、氣干燥、純化、氫氣露點監(jiān)測、氫氣泄漏監(jiān)測、水超純化處理、水箱液位監(jiān)測、電解水水質監(jiān)測 Nitrogen purge, gas drying, purification, hydrogen dew point monitoring, hydrogen leak monitoring, water ultra-purification treatment, water tank level monitoring, electrolytic water quality monitoring
|